🚀 Heat Exchanger Sizing (LMTD)
Compute the LMTD and required heat-transfer area from heat duty, fluid temperatures and the overall heat-transfer coefficient.
📐 计算公式
LMTD = (ΔT₁−ΔT₂) / ln(ΔT₁/ΔT₂);A = Q / (K · LMTD)
依据对数平均温差(LMTD)法,对逆流或顺流布置分别计算 LMTD,再按热流量 Q 与总传热系数 K 求所需换热面积 A。
💡 逆流:ΔT₁=Th,in−Tc,out,ΔT₂=Th,out−Tc,in;顺流:ΔT₁=Th,in−Tc,in,ΔT₂=Th,out−Tc,out;LMTD=(ΔT₁−ΔT₂)/ln(ΔT₁/ΔT₂);A=Q×1000/(K×LMTD)。
Formula & Standard References
| Item | Formula / Note | Source / Standard |
|---|---|---|
| Heat transfer equation | Q = K·A·ΔT_m | Heat transfer |
| LMTD | ΔT_m = (Δt₁ − Δt₂)/ln(Δt₁/Δt₂) | LMTD method |
| Overall coefficient | 1/K = 1/h₁ + δ/λ + 1/h₂ + R_f | Thermal resistance |
| Effectiveness-NTU | ε = f(NTU, C_r) verification | ε-NTU method |
| Design standard | Shell-and-tube heat exchanger code | GB/T 151-2014 |
| Fouling resistance | R_f by fluid, water 0.0002 | TEMA standards |
⚠️ 注意事项
- 传热系数 K 需根据换热器类型与流体选取:水-水约 800~1500,汽-水约 2000~4000,气-气约 20~60 W/m²·K
- 逆流 LMTD 大于顺流,所需面积更小,工程中优先采用逆流布置
- 非纯逆/顺流需乘以 LMTD 修正系数 Ft(一般 0.8~1.0),本工具未计入