📐 计算公式
分度值极限误差(本页代码口径):极限误差 = ±分度值÷2(读数按半分度估读);联动量:下限 = −分度值÷2、分度值倒数 = 1÷max(分度值,10⁻¹²)、1/4 分度 = ×0.25、3/4 分度 = ×0.75、1.5 倍分度 = ×1.5。校验:无强校验,空值按 0 兜底。判据:无固定分级,附常用量具分度值对照——钢直尺 0.5、游标卡尺 0.02、千分尺 0.01、电子天平 0.0001。

读数误差约 ± 分度值/2。

📏 典型量具分度值与极限误差(误差 = 分度值 / 2)

📈 极限误差随分度值变化(±lc/2)

Formula & Standard References

Item Formula / Note Source / Standard
Uncertainty from finite resolution With half-width a = delta_x/2, a rectangular distribution gives u = a/sqrt(3) = delta_x/(2·sqrt(3)) JCGM 100:2008, Guide to the Expression of Uncertainty in Measurement (GUM)
Rectangular distribution assumption Readings are equally likely within ±delta_x/2, hence division by sqrt(3) JCGM 100:2008, Guide to the Expression of Uncertainty in Measurement (GUM)
Definition of resolution The smallest difference in indications that can be meaningfully distinguished JCGM 200:2012, International Vocabulary of Metrology (VIM)
When resolution is inadequate Replace or upgrade the equipment when the resolution component dominates ISO/IEC 17025:2017, General requirements for the competence of testing and calibration laboratories
📌 计算说明
  • 目视估读通常 ±0.5 分度。
  • 数显量具无此误差。

📚 深度解析:分度值误差

💡 常见使用场景

公式
估读误差约 ±(0.5~1)*分度值。例:卡尺 0.02 mm 分度,读数误差约 ±0.01~0.02 mm。
分度值 0.005 mm
读数极限误差=±0.005/2=±0.0025 mm,下限 −0.0025。这是按读数规则估算的最大误差,实际读数误差通常小于它。

❓ 常见问题(FAQ)

分辨率?
数显分辨率即最小显示位,记录到一位估读。
与不确定度?
贡献 B 类不确定度分量。