🚀 Pump Sizing Calculator
From flow rate, head, fluid density and pump efficiency, computes hydraulic power, shaft power and motor power, then recommends a standard motor rating.
📐 計算公式
軸功率 P_s = ρ·g·Q·H / (3600×1000×(η/100)),η 按 % 輸入;配電機 P = P_s × K
由流量 Q、揚程 H、介質密度 ρ 與泵效率 η 計算軸功率,乘以安全係數 K 並依據標準電機功率等級推薦匹配電機;按比轉速推薦泵型。
💡 水力功率 Ph=ρgQH/(3600×1000) kW;軸功率 Psh=Ph/(η/100) kW;電機功率 Pm=Psh×K;比轉速按頁面輸入轉速 n 計算。
Formula & Standard References
| Item | Formula / Note | Source / Standard |
|---|---|---|
| Head and flow | pump head falls as flow rises and the duty point is where curves intersect | ISO 9906:2012, pump performance testing |
| Net positive suction head | available suction head must exceed the required value to avoid cavitation | ISO 9906:2012, pump performance testing |
| Shaft power | shaft power is density times gravity times flow times head over efficiency | ISO 5199:2002, centrifugal pump technical |
⚠️ 注意事項
- 清水密度 1000 kg/m³,泥漿約 1100~1300,油類約 800~900
- 泵效率一般 60%~85%,小型泵取低值,大中型離心泵取高值
- 安全係數通常取 1.1~1.3,小功率泵取高值以防過載
- 按 Enter 快速計算,Ctrl/Cmd + Enter 複製結果;純前端執行,資料不上傳
🕘 最近計算
暫無計算記錄