Hazen-Williams Head Loss Calculator

Compute head loss h_f = 10.67*L*Q^1.852/(C^1.852*D^4.87) from flow, pipe length, roughness coefficient C and diameter (SI units).

📐 计算公式
Hazen-Williams 沿程水头损失(本页代码口径):h_f=10.67×L×Q^1.852÷(C^1.852×D^4.87)(m,Q 流量 m³/s、L 管长 m、C 粗糙系数、D 管径 m)。联动量:无其它派生项,结果保留 3 位小数。校验:四字段经输入守卫必填且须为合法数值,否则提示并中止。判据:无固定分级,h_f 与流量 1.852 次方成正比、与管径 4.87 次方成反比、与管长线性相关。

由流量、管长、粗糙系数 C 与管径,按 h_f = 10.67·L·Q^1.852/(C^1.852·D^4.87) 计算水头损失(SI)。

📌 计算说明
  • 适用于水温约 4–25℃ 的给水管道;C 值:新钢管≈120–140,旧管≈80–100。
  • 单位为 SI(Q: m³/s,D: m,结果 m)。

📐 Hazen-Williams Reference

Constants and standards used on this page with their authoritative sources, for verification and citation.

Quantity Value Unit Source
SI constant 10.67 (Q in m³/s, D and L in m) SI form of the Williams & Hazen (1920) hydraulic tables
US customary constant 4.727 (Q in ft³/s, d in ft) Williams & Hazen (1920) / AWWA practice manuals
Flow / diameter exponents 1.852 / 4.87 dimensionless Empirical exponents of the Hazen-Williams fit
Roughness C (new steel / old cast iron) 130–140 / 100–110 dimensionless Engineering experience values from water-supply design manuals and AWWA handbooks; no internationally standardised value
Applicability Clean water near 20 °C, v ≲ 3 m/s, D ≳ 50 mm — Accepted range of the Hazen-Williams empirical formula

Note: Hazen-Williams has no Reynolds-number correction; errors can exceed 20% once temperature or viscosity departs markedly from 20 °C water. Use Darcy-Weisbach with the Colebrook equation in those cases.

📚 深度解析:海曾-威廉公式水头损失

💡 常见使用场景

标准算例
Q=0.01 m³/s、L=100 m、C=120、d=0.1 → h_f=10.67×100×0.01^1.852/(120^1.85×0.1^4.87)≈0.25 m。
C 值影响
C 从 120 降到 100(旧管),同条件损失增约 40%,结垢显著抬升能耗。

❓ 常见问题(FAQ)

C 是什么?
海曾-威廉粗糙系数,新钢管 130~140、旧管或水泥管更低,材质越光滑越大。
和达西比?
海曾为给水经验式,含 C 不直接显 f;达西更通用但需 f(Re,ε)。

Formula & Standard References

Item Formula / Note Source / Standard
Hazen-Williams equationv = 0.849·C·R^0.63·i^0.54 (SI, R in m, i dimensionless)Hazen & Williams 1905, AWWA
ApplicabilityOnly for water in turbulent flow (Re ≈10⁴–2×10⁶), not gas or hot waterWater-supply design handbook
C value referencePVC/PE 140–150, new cast iron 130, old steel 90–110 (declines with tuberculation)Water-supply engineering tables
Versus DarcyHW is convenient for hand calc but less fundamental than Darcy-WeisbachMethod-comparison literature