熱水器容量與升數選型計算器
📐 Formula
🧮 Inputs
Use 2 for two simultaneous showers; 1 for staggered showers needs a smaller tank.
Standard showerheads use about 6–10 L/min; high-pressure models can reach 12.
Storage units are commonly 2–3 kW; enter 6–24 kW for instantaneous models from the nameplate.
🕘 Recent Calculations
Common Capacity & Flow References
| 型別 | 常見規格 | 適用場景 | 注意 |
|---|---|---|---|
| 儲水式電熱水器 | 40 / 50 / 60 / 80 / 100 L | 1–2 人 40–50 L;3 人 60–80 L;4 人以上 80–100 L | 看同時洗澡人數與加熱功率,冬季進水溫度低要上浮 |
| 燃氣熱水器 | 10 / 12 / 16 / 20 L/min(ΔT25) | 單衛 10–12 L;雙衛同時 16 L 以上 | 升數按溫升 25°C 標,冬季溫升大時實際流量會下降 |
| 即熱式電熱水器 | 6 / 8 / 12 / 18 / 24 kW | 小流量單點 6–8 kW;8 L/min 淋浴約 14 kW 起 | 需獨立專線與空開,老房先核入戶容量 |
| 混水閥 / 花灑 | 6–12 L/min | 普通 8 L/min;大花灑 10–12 L/min | 流量越大,儲水容量與即熱功率都要上浮 |
Specifications are common household references; the nameplate, manual and installation conditions still decide.
📌 Notes
- Storage capacity assumes 60°C water and 80% usable volume; actual usable hot water depends on tank design, inlet temperature, mixing valve and insulation, so go one size up in winter.
- Gas ratings are at a 25°C rise, not actual outlet flow; with 5°C inlet and 40°C target the rise is 35°C, so actual flow is roughly rated × 25 ÷ 35.
- Instantaneous power assumes all electricity becomes heat and ignores efficiency and line losses; a licensed electrician must verify the breaker and wire size against the nameplate and service capacity.
- Daily cost assumes one full heat per day for the household; standby, time-of-use tariffs and mixing ratios will change it.
🔗 Related Tools
📚 Deep Dive: Capacity, Flow Rating and Power
For storage, start with simultaneous showers, then the gap between users. Two 10-minute showers at 8 L/min need about 160 L mixed water at 40°C, about 89 L of 60°C water, and about 111 L tank volume at 80% usable, so choose 120 L or stagger users with an 80 L tank.
Gas ratings assume a 25°C rise. With 5°C inlet and 40°C target the rise is 35°C, so a 16 L/min unit delivers only about 11.4 L/min; two simultaneous showers need a larger rating based on total flow.
For instantaneous electric units, power and wiring matter more than capacity. 8 L/min at a 25°C rise needs about 14 kW, roughly 63 A at 220 V, usually an 80 A breaker and 10 mm² dedicated line; when service capacity is limited, storage or gas is often more practical.
❓ FAQ
- 儲水式 60 L 夠幾個人洗?
- 按 40°C 混水、進水 15°C、儲水 60°C 估算,60 L 約可供 1 人洗 10–12 分鐘;兩人連續洗要等加熱,冬季建議 80 L 起。
- 燃氣 12 L 和 16 L 差多少?
- 差在溫升 25°C 時的額定流量。單衛 8 L/min 淋浴 12 L 足夠;雙衛同時開、或冬季進水很冷時,16 L 以上更穩。
- 即熱式一定要改電嗎?
- 多數情況要。8 L/min 淋浴約 14 kW,普通 16 A 插座帶不動;需獨立專線、專用空開,並由電工核對入戶容量與線徑。
- 容量越大越費電嗎?
- 加熱同樣水量所需能量接近,大容量主要增加保溫散熱與佔地。按人數選合適容量,比盲目加大更省電。