♻️ Waterproofing Material Inspection

Composite compliance check for bonding and waterproofing materials: scores bond strength, impermeability grade and environmental pass rate.

📐 工作原理與說明
逐項按規範限值判定(≤ 上限 / ≥ 下限 / 落在區間內),全部符合判合格,任一不符即不合格
本頁把三項實測值與固定閾值逐項比較,僅供自檢,不生成檢測報告、不作驗收依據;純前端執行,資料不上傳。
GB/T 16777 防水材料≥0.5 MPa
GB/T 50082 抗滲等級≥P6
GB 18582 有害物質達標率≥90%

Formula & Standard References

Item Formula / Note Source / Standard
Bond strength testTile bond strength ≥0.4 MPa per piece; pull-off tests sampled on siteJGJ 110-2017 Test Standard for Bond Strength of Facing Tiles
Water impermeabilityP6 concrete withstands 0.6 MPa water head; coating membrane ≥1.5 mm thickGB 50108 / GB 50208-2011 Acceptance Code for Underground Waterproofing
Environmental re-testIncoming coatings/adhesives re-tested for VOC and free formaldehyde by categoryGB 50325-2020 Standard for Indoor Environmental Pollution Control
Witnessed samplingSampling under witness supervision, tested by accredited lab, report citing the standardMOHURD witnessed sampling and testing provisions

📚 深度解析:防水材料進場三項檢測判定(粘結/抗滲/環保)

💡 常見使用場景

  • 防水工程材料自檢:按粘結強度、抗滲等級、環保達標率三項判定合格性
  • 報告可用性:三項全合格方可出具僅供自檢,不作為驗收依據的檢測報告
  • 整改指引:任一項不達標提示換料或複檢
方法
逐項判定:粘結強度≥0.5MPa、抗滲等級≥6 級、環保達標率≥90%;三項均滿足為合格,否則整改後重測。三項閾值引自對應防水材料產品標準與 GB 18580 環保要求。
算例
粘結 0.8MPa(≥0.5 ✓)、抗滲 8 級(≥6 ✓)、環保達標率 92%(≥90 ✓):三項全合格 → 判定合格,報告可用於驗收。若環保降到 85% 則不合格,須換料或複檢。

❓ 常見問題(FAQ)

抗滲等級數字越大越好?
是的,抗滲等級(P6/P8…)數字即承受的水壓力 MPa 數,越高抗滲越強;本工具取 ≥6 級為合格線,重要部位常要求更高。
三項合格就絕對防水?
僅代表進場自檢符合所列三項閾值;完整防水效果還取決於施工工藝、節點處理與閉水試驗,須以正式檢測與設計要求為準。
⚠️ 使用說明與注意事項