维氏硬度计算器

Vickers Hardness Calculator

Compute Vickers hardness HV = 1.854·F/d² from indentation diagonal d and test force F (converted to kgf).

📐 计算公式
维氏硬度(本页代码口径):HV=1.854×F(kgf)÷d²,试验力先由牛顿换算千克力 F(kgf)=F(N)÷9.80665,d 为压痕对角线长度(mm);联动量:对比 kgf 基准=HV÷9.80665、压痕表面积=d²÷1.854(mm²)、对角线平方=d²。校验:两字段经输入守卫必填且须为合法数值,否则提示并中止。判据:无固定分级,漏除 9.80665 会把结果放大约 10 倍,载荷越小或压痕越大硬度值越低。

维氏硬度由压痕对角线长度与试验力求得(F 换算为 kgf)。

Formula & Standard References

Item Formula / Note Source / Standard
Vickers hardness HV = 1.854 · F / d^2, with F in kgf and d the mean diagonal in mm ISO 6507-1:2018, Metallic materials - Vickers hardness test - Part 1: Test method
Indenter geometry The indenter is a diamond pyramid with a 136° angle between opposite faces ISO 6507-1:2018, Metallic materials - Vickers hardness test - Part 1
Origin of the constant The constant 1.854 follows from the indenter geometry and unit conversion via 2·sin(136°/2) ISO 6507-1:2018, Metallic materials - Vickers hardness test
Test force range Vickers covers a wide force range from micro to conventional hardness ISO 6507-1:2018, Metallic materials - Vickers hardness test - Part 1
📌 计算说明
  • HV = 1.854·F_kgf/d²;F 以 kgf 计。
  • 10 kgf、d=0.5mm → HV≈74.2。

📚 深度解析:维氏硬度 HV

💡 常见使用场景

公式
HV = 1.854*F/d^2(F 载荷 N、d 两对角线均值 mm,结果 kgf/mm2 或换算 GPa)。压痕小、载荷可调,从软到硬通用。
优势
几何自相似,载荷无关(同材料),适合薄镀层、焊缝、微小区域,结果可比性强。

❓ 常见问题(FAQ)

维氏为什么全范围通用?
正四棱锥压痕几何与载荷无关,软硬材料同公式;洛氏需换标尺、布氏限于中硬。
HV 和 HB 数值可比吗?
中硬区两者近似相等;高硬/薄层维氏更准,HB 偏大或不适用。