热水器容量与升数选型计算器
📐 Formula
🧮 Inputs
Use 2 for two simultaneous showers; 1 for staggered showers needs a smaller tank.
Standard showerheads use about 6–10 L/min; high-pressure models can reach 12.
Storage units are commonly 2–3 kW; enter 6–24 kW for instantaneous models from the nameplate.
🕘 Recent Calculations
Common Capacity & Flow References
| 类型 | 常见规格 | 适用场景 | 注意 |
|---|---|---|---|
| 储水式电热水器 | 40 / 50 / 60 / 80 / 100 L | 1–2 人 40–50 L;3 人 60–80 L;4 人以上 80–100 L | 看同时洗澡人数与加热功率,冬季进水温度低要上浮 |
| 燃气热水器 | 10 / 12 / 16 / 20 L/min(ΔT25) | 单卫 10–12 L;双卫同时 16 L 以上 | 升数按温升 25°C 标,冬季温升大时实际流量会下降 |
| 即热式电热水器 | 6 / 8 / 12 / 18 / 24 kW | 小流量单点 6–8 kW;8 L/min 淋浴约 14 kW 起 | 需独立专线与空开,老房先核入户容量 |
| 混水阀 / 花洒 | 6–12 L/min | 普通 8 L/min;大花洒 10–12 L/min | 流量越大,储水容量与即热功率都要上浮 |
Specifications are common household references; the nameplate, manual and installation conditions still decide.
📌 Notes
- Storage capacity assumes 60°C water and 80% usable volume; actual usable hot water depends on tank design, inlet temperature, mixing valve and insulation, so go one size up in winter.
- Gas ratings are at a 25°C rise, not actual outlet flow; with 5°C inlet and 40°C target the rise is 35°C, so actual flow is roughly rated × 25 ÷ 35.
- Instantaneous power assumes all electricity becomes heat and ignores efficiency and line losses; a licensed electrician must verify the breaker and wire size against the nameplate and service capacity.
- Daily cost assumes one full heat per day for the household; standby, time-of-use tariffs and mixing ratios will change it.
🔗 Related Tools
📚 Deep Dive: Capacity, Flow Rating and Power
For storage, start with simultaneous showers, then the gap between users. Two 10-minute showers at 8 L/min need about 160 L mixed water at 40°C, about 89 L of 60°C water, and about 111 L tank volume at 80% usable, so choose 120 L or stagger users with an 80 L tank.
Gas ratings assume a 25°C rise. With 5°C inlet and 40°C target the rise is 35°C, so a 16 L/min unit delivers only about 11.4 L/min; two simultaneous showers need a larger rating based on total flow.
For instantaneous electric units, power and wiring matter more than capacity. 8 L/min at a 25°C rise needs about 14 kW, roughly 63 A at 220 V, usually an 80 A breaker and 10 mm² dedicated line; when service capacity is limited, storage or gas is often more practical.
❓ FAQ
- 储水式 60 L 够几个人洗?
- 按 40°C 混水、进水 15°C、储水 60°C 估算,60 L 约可供 1 人洗 10–12 分钟;两人连续洗要等加热,冬季建议 80 L 起。
- 燃气 12 L 和 16 L 差多少?
- 差在温升 25°C 时的额定流量。单卫 8 L/min 淋浴 12 L 足够;双卫同时开、或冬季进水很冷时,16 L 以上更稳。
- 即热式一定要改电吗?
- 多数情况要。8 L/min 淋浴约 14 kW,普通 16 A 插座带不动;需独立专线、专用空开,并由电工核对入户容量与线径。
- 容量越大越费电吗?
- 加热同样水量所需能量接近,大容量主要增加保温散热与占地。按人数选合适容量,比盲目加大更省电。