🧪 Coolant Concentration Top-Up

From system capacity and current versus target concentration, computes how much concentrate or water to add, covering both direct top-up and drain-and-refill exchange.

📐 计算公式
循环水浓度调节(补液置换口径):|c₂−c₁| <0.01 判浓度已达标免调;提浓(c₂ > c₁):补原液量 = V×(c₂−c₁) ÷ (cₛ−c₂)、补加后总容量 = V + 补原液量、排液置换量 = 补原液量(保持体积);稀释(c₂ < c₁):补清水量 = V×(c₁−c₂) ÷ c₂、补加后总容量 = V + 补清水量、排液置换量 = 补清水量。校验:V、c₁、c₂、cₛ 非空守卫,任一非数或 V=0 提示「请输入有效数值(系统容量需大于 0)」,c₂ > cₛ 提示目标浓度不能高于原液浓度、提浓时 c₂ ≥ cₛ 提示目标浓度需小于原液浓度才能通过补原液提高。
根据系统容量与当前/目标浓度,计算需补充的原液量或水量(支持直接补加与排液置换两种方案)
💡 提高浓度:补原液 V×(c₂−c₁)/(cₛ−c₂);降低浓度:补清水 V×(c₁−c₂)/c₂。排液置换方案可保持体积不变。

Formula & Standard References

Item Formula / Note Source / Standard
Mixing concentration c_final = ( c1 · V1 + c2 · V2 ) / ( V1 + V2 ), from solute conservation Harris DC, Quantitative Chemical Analysis, solution preparation
Coolant freezing point The freezing point of glycol-water mixtures varies with concentration, with an optimum giving the minimum ASTM D1177, Standard Test Method for Freezing Point of Aqueous Engine Coolants
Volume versus mass fraction Conversion between them requires the solution density; volume ratios are not mass ratios IUPAC, Compendium of Chemical Terminology (Gold Book)
Dilution by topping up Adding plain water lowers the coolant concentration and raises the freezing point ASTM D1177, Standard Test Method for Freezing Point of Aqueous Engine Coolants
⚠️ 注意事项
  • 浓度指冷却液中有效成分(乙二醇/防锈剂等)的体积百分比
  • 补加后系统体积会增加,排液置换方案为先排出等量旧液再加入原液/水
  • 实际维护应同步检测 pH 值、冰点与防锈性能,避免单一指标调整
  • 按 Enter 快速计算,Ctrl/Cmd + Enter 复制结果;纯前端运行,数据不上传

🕘 最近计算

暂无计算记录